Cooling for Rising Rack Density
Match cooling architecture to heat loads, room conditions and planned growth with air, hybrid and liquid-cooling systems.
Search pages, insights, and customer stories.
DATA CENTERS & DIGITAL INFRASTRUCTURE
CoolSys engineers data center power and cooling solutions for hyperscale, colocation, edge, enterprise and AI/HPC environments. Our teams coordinate thermal systems, resilient power, commissioning, and ongoing service around uptime, density and speed-to-power demands.
INDUSTRY PRIORITIES
CoolSys connects data center power and cooling with maintenance, controls, energy and lifecycle priorities to support availability as workloads change. From engineering and procurement through installation, commissioning and service, we assess site conditions, loads, growth plans and utility access together, with energy and water use in view.
Match cooling architecture to heat loads, room conditions and planned growth with air, hybrid and liquid-cooling systems.
Address utility constraints and continuity requirements with coordinated onsite generation, storage, UPS and distribution strategies.
Verify that installed power, cooling and controls work together before systems enter critical service.
Evaluate thermal and energy decisions together to advance facility performance and resource-use goals.
HOW COOLSYS HELPS
CoolSys delivers engineering, sourcing, project coordination, installation, commissioning and service for integrated power and cooling, including MEP and fire protection needs. Bridge-to-Grid strategies can include CHP, standby generation, batteries, UPS and microgrid controls. Cooling may use air, hybrid or liquid architectures. Our own crews coordinate construction, startup and operations.
Licensed engineering throughout the U.S. connects MEP, refrigeration, controls and fire protection expertise with thermal loads, power, airflow, redundancy and sustainability goals.
Our OEM-agnostic recommendations prioritize project performance, efficiency and redundancy. CoolSys coordinates equipment selection, installation, startup, and commissioning across cooling and power systems, with handover planned as part of the work.
CoolSys crews maintain, monitor, service, upgrade and recommission power, cooling and fire-protection equipment, giving facility teams direct access to those responsible for field execution.
SOLUTIONS & SERVICES
Choose solution areas that match your facility’s project scope, operating priorities and growth plan.
Explore HVAC and refrigeration equipment, installation and service applicable to data center thermal infrastructure.
Explore →Review central plant and applied-system capabilities for chilled-water production, heat rejection and related facility infrastructure.
Explore →Explore onsite generation and standby power strategies for continuity and utility-interconnection needs.
Explore →Develop coordinated engineering and design recommendations for data center power, cooling and facility systems.
Explore →CoolSys crews self-perform installation of power and cooling equipment, system integration and project execution.
Explore →CoolSys technicians maintain, monitor and service critical power and cooling equipment through ongoing programs and field support.
Explore →INDUSTRY EXPERTISE
CoolSys integrates MEP, refrigeration, controls and fire protection expertise with airflow analysis and thermal optimization.
OEM-agnostic selection covers CRACs, CRAHs, chillers, CDUs, pumps, air handlers, UPS, batteries, CHP and microgrid controls.
Design considers loads, site conditions, power availability, operating plans, PUE and WUE goals, alongside applicable codes, permits, utility and refrigerant requirements.

CASE STUDIES
CASE STUDY
Integrated CHP commissioning, maintenance, and monitoring helped a data center improve resilience, reduce emissions, and manage energy costs.
READ CASE STUDY →
CASE STUDY
CoolSys restored CHP performance at a New York City cancer center through maintenance, plant balancing, and continuous remote monitoring.
READ CASE STUDY →
CASE STUDY
CHP commissioning, maintenance, and monitoring strengthened energy resilience for a university village with critical heating and hot-water needs.
READ CASE STUDY →No case studies match your search. Try another term or select all case studies.
The right system depends on facility size, workload density, heat loads and site conditions. CoolSys works with air, hybrid and liquid-cooling architectures, including CRACs, CRAHs, chillers, CDUs, pumps and direct-to-chip infrastructure. Our engineering teams assess airflow and thermal conditions to guide equipment selection and system integration.
CoolSys develops Bridge-to-Grid strategies that combine gas-to-power, CHP, or standby generation, battery energy storage, UPS architectures, power distribution, and microgrid controls. The configuration depends on site conditions, utility requirements, project schedule and operating goals. We coordinate power planning with the facility’s cooling systems and other infrastructure needs.
Yes. CoolSys provides engineering and project capabilities across power and cooling, including onsite prime generation, CHP, UPS, batteries, microgrids, HVAC equipment and liquid-cooling infrastructure. Our teams coordinate these systems through project planning, self-performed installation, commissioning, and ongoing maintenance for critical facility equipment.
CoolSys provides equipment startup, commissioning, plant balancing, optimization, maintenance, monitoring, emergency response and recommissioning. CoolSys technicians and crews self-perform construction, installation, and service work. Monitoring and response coverage varies by service agreement and location.
Yes. CoolSys self-performs construction, installation, and service work with its own technicians and crews. National coordination with local self-performing teams supports direct accountability, consistent work standards, and documentation from field execution.
CoolSys considers PUE and WUE goals when engineering and optimizing data center systems. Work includes airflow and thermal analysis, cooling-equipment selection, system balancing and energy-strategy review. Facility teams establish specific targets and measurement methods with the project team based on site requirements and operating priorities.
DATA CENTERS & DIGITAL INFRASTRUCTURE
Discuss your facility, workload, power constraints and cooling priorities with CoolSys. We review project scope and identify relevant engineering, equipment, self-performed installation and service capabilities.